TUN-4043 Addres Heat Detector for POLON 4100,4200

Price: 22,25 EUR
Type addressable, point Category to work in normal conditions Type temperature Operational voltage 16,5 VDC - 24,6 VDC Quiescent current consumption ≤ 150 µA Detector class A1, A2, B, A2S, BS, A1R, A2R, BR acc. to PN-EN 54-5 Addressing address coding automatically from control panel Operating temperature range from -25°C to 65°C Relative humidity to 95% at 40°C Dimensions of detector with base Ф115 x 54mm Weight 0.20 kg Enclosure colour white

DOR-4043 Addres Smoke Detector for POLON 4100,4200

Price: 21,06 EUR
Type addressable, point Category to work in normal conditions Type smoke Operational voltage 16,5 VDC - 24,6 VDC Quiescent current consumption ≤ 150 µA Detected test fires TF2 to TF5 Addressing address coding automatically from control panel Operating temperature range from -25°C to 55°C Relative humidity to 95% at 40°C Dimensions of detector with base Ф115 x 54mm Weight 0.20 kg

TUN-4046 Addressable Heat Detector

Price: 23,40 EUR
• heat sensor • soft addressing • programmable temp. class • low current consumption • built-in short circuit isolator • TUN-4043 for POLON 4100 and POLON 4200 • EN 54-7

DOR-4046 Addressable Smoke Detector

Price: 22,22 EUR
• IR smoke sensor • soft addressing • programmable parameters • low current consumption • automatic drift compensation • built-in short circuit isolator • DOR-4043 for POLON 4100 and POLON 4200 • EN 54-5

DOT-4046 Addressable Smoke and Heat Detector

Price: 30,45 EUR
• IR smoke sensor • heat sensor • soft addressing • programmable parameters • low current consumpti on • automati c drift compensati on • built-in short circuit isolator • EN 54-5, EN 54-7

PPW-40REx Triple IR Flame Detector, ATEX approved

Price: 2788,00 EUR
Type with alarm and error relays Category to work in explosive atmosphere Type flame Operational voltage 24 VDC (18 - 36 VDC) Current consumption in alarm mode max. power consumption 9 W for 36VDC in alarm state with heater on Detector class II 2G Ex ib II C T6 Gb + II 1D Ex ta IIIC T85oC IP66 Addressing detector with alarm and fault relays Operating temperature range from -40°C to 75°C Relative humidity to 95% at 40°C Dimensions of detector with base 147 x 145x 162mm Weight 2.0 kg Enclosure colour black Other parameters Housing protection level - IP66, Current output - 4 - 20 mA, Directional correlation horizontal - 80⁰, Directional correlation vertical - 75⁰, Cables 0,5mm2 to 2,5mm2 shielded, Cable glands - M25, Housing material - aluminium

DUR-40Ex Universal Optical Smoke Detector,ATEX app

Price: 63,20 EUR
Type conventional, point Category to work in normal conditions Type smoke Operational voltage 12 VDC- 28 VDC Quiescent current consumption ≤ 60 µA Current consumption in alarm mode 20 mA Detector class II 2G Ex ib II C T6 Gb Detected test fires TF1 to TF5 and TF8 Addressing conventional detector without addresses Operating temperature range from -25°C to 55°C Relative humidity to 95% at 40°C Dimensions of detector with base Ф115 x 54mm Weight 0.15 kg

G-40 Detector’s Base

Price: 4,05 EUR
• for all addressable and conventi onal detectors • increased ti ghtness • screwless connecti on • shield connector included • opti onal assembly ring P-40 • opti onal base att achment PG-40

DOP-6001 Addressable/Convent Beam Smoke Detector

Price: 349,05 EUR
• IR smoke detecti on • soft addressing • automati c drift compensati on • auto-alignment functi on • built-in laser pointer • programmable sensiti vity • low current consumpti on • built-in short circuit isolator • EN 54-12, EN 54-17

E39-R8 Prismatic Reflector for DOP-6001 (5-50m)

Price: 19,90 EUR
Prismatic reflector for beam smoke detector 5-50m

4XE39-R8 Set of reflectors for DOP6001 (50-100m)

Price: 92,50 EUR
Set of reflectors for beam smoke detector 50-100m

LS-40 Service Mirror for DOP-6001

Price: 26,90 EUR
Service mirror for beam smoke detector

POLON 4100 Control Panel 2 Loops 128 addresses

Price: 895,00 EUR
2 loops with 64 addresses • 3 supervised relay outputs • 2 monitoring inputs • supervised signalling line • 240x320pix graphic • EN 54-2 display

POLON 4200 Control Panel 4 loops 256 addresses

Price: 1393,00 EUR
Supply voltage: main 50Hz, 230V +10% - 15% Supply voltage: standby 24V 17Ah to 38Ah HP7-12 KOBE Max. quiescent current consumption 0.4A Max. current consumption from power grid 0.8A Max. loop capacity 300nF Max. loop current 50mA (20mA) Max. current for auxiliary devices 0.1A Line elements installed in detection lines analogue detectors type 4043, 4046; manual call points ROP-4001, ROP-4001H, ROP-4001M, ROP-4001MH; adapters ADC-4001M, ADC-4001; sirens SAL-4001; input/output devices EKS-4001 multi-output devices EWS-4001; multi-input devices EWK-4001 Potential-free supervised relay output current load 1A/24V Number of addressable lines 4 Numer of alarming variants 14 Signaling lines (potential) 2 Number of detectors in line 64 Auxiliary devices output current carrying capacity 500mA/24V ADC-4001M current consumption from detection line 0.5, 1.33, 2.2, 2.5, 6.8, 16mA (w zależności od trybu pracy) Current consumption by elements like detectors, manual call points, signalling devices, EKS, EWS, EWK-4001 from 130uA to 170uA (depending from the element type) Programmable outputs 8 relays 1A/24V; 1 linia sygnałowa o obciążalności 0.5A/24V; 1 linia sygnałowa o obciążalności 0.1A/24V; Programmable inputs 2 monitoring inputs

POLON 4900 Control Panel 4/8Loops 508/1016 Address

Price: 2047,50 EUR
• 4 loops with 127 addresses • optional 4 loops card • network operation - MSI-48 required (up to 31 panels) • 16 supervised relay outputs • 8 monitoring inputs • 8 supervised signalling lines • redundancy “on board” • built-in printer • 240x320pix graphic display • EN 54-2

TSR 4000 Parallel Repeater for Addressable Panel

Price: 743,00 EUR
• up to 16 TSRs connected to one FACP • relay output • signalling line • LCD display

SAL-4001 Addressable Signalling Device

Price: 49,15 EUR
Type tone, acustic, low current Installation internal Version addressable Supply voltage 16VDC - 32.0VDC Supply voltage from detection line 16.5VDC - 24.6VDC Supply voltage of external power supply unit 16VDC - 32VDC Current consumption from battery ≤ 10mA in alarm mode Current consumption from external power supply ≤ 16µA in alarm mode in alarm mode Sound level with supply from external PSU 100dB Operating temperature range from -10°C to 55°C Housing ingress protection IP 21C Dimensions Ф 115x54 mm Weight 200g Other parameters acc. to PN-EN 54-3

SAW-6001 Addressable Siren with tones

Price: 93,40 EUR
Type tone, acustic, low current Installation internal Version addressable Supply voltage 9.6VDC - 30.0VDC Supply voltage from detection line 16.5VDC - 24.6VDC Supply voltage of external power supply unit 9.6VDC - 30VDC Current consumption from external power supply ≤ 50µA with 24 VDC supply with 24 VDC supply Sound level to 103dB Operating temperature range from -25°C to 55°C Housing ingress protection IP 21C Dimensions Ф 115x70 mm Weight 200g Other parameters acc. to PN-EN 54-3, Battery 6LR61 working time in alarm mode - min 3h, Battery 6LR61 working time in quiescent mode - 2 to 5 years

ROP-4001M Addressable Manual Call Point

Price: 30,45 EUR
• indoor and outdoor applicati on • fl ush mounti ng • wall mounti ng with assembling frame • soft addressing • low current consumpti on • built-in short circuit isolator • EN 54-11 (type B)

RM-60-R Assembling Frame for ROP-4001M

Price: 1,65 EUR
Assembling frame (for manual call points, on-plaster mounting)

EKS-4001 Input/output Addressable Device(2in/1out)

Price: 38,60 EUR
one relay output (2 A, 30 V) • 2 monitoring inputs • 3 types of enclosures • IP 67 • built-in short circuit isolator • EN 54-18, EN 54-17

1xEKS Case (for 1 EKS-4001)

Price: 33,95 EUR
Case (for 1 EKS-4001)

EWK-4001 Multi-Input Addressable Device (8in)

Price: 64,35 EUR
• eight monitoring inputs • integrated enclosure • IP 67 • built-in short circuit isolator • EN 54-18 Type: Multi-input supervising device Purpose: The EWK-4001 addressable multi -input supervising element is designed for monitoring of external fire protection equipment (e.g. fire proof door, fire damper)., and to receive information about fire alarm from the detectors with potential-free change-over contact, or other fire alarm systems,e.g. IGNIS 1000. This device can be installed indoors or outdoors. Cooperation: POLON 4100, POLON 4200, POLON 4800, POLON 4900 and POLON 4500 system fire alarm control panels.

EWS-4001 Multi -Output Device (8out)

Price: 169,65 EUR
• Eight relay output (2 A, 30 V) • integrated enclosure • IP 67 • built-in short circuit isolator • EN 54-18 Type: Multi-output control device Purpose: The EWS-4001 addressable multi -output control device is designed to control different fire-fighting automatic equipment, in particular for switching-on pre-fire warning sound systems and synoptic signs.This element can be installed indoors or outdoors. Cooperation: POLON 4100, POLON 4200, POLON 4800, POLON 4900 and POLON 4500 fire alarm control panels.

Gemos "SMART" Visualization system

Price: 0,50 EUR
GEMOS "Smart" is a software designed to manage the security of the facility in the field of surveillance and visualization of elements of the POLON 4000 fire detection system. On the computer screen, on the premises plan, the status of all the POLON detection and execution elements is indicated. It also allows for remote acknowledgement or reset the system. GEMOS Smart supports the security services of the facility by displaying predefined emergency procedures in case of emergency. Eligible users, such as the user and the administrator of the object, have the ability to view the history of events and actions taken by the security services according to any search criteria, and to generate reports according to established templates. GEMOS is an efficient tool that assists in the creation and modification of facility protection plans as well as in effectively and effectively raising the level of building safety. Application: The GEMOS "Smart" range of applications is dedicated to small to mid-sized objects where one maintenance post is planned for later expansion. Expandability: GEMOS "Smart" is scalable and flexible, easy to keep up with, and changing user needs. It can be upgraded to the GEMOS Standard version, which is a more advanced management system for more different security systems. They are, for example, access control, intrusion and fire alarm systems, CCTV systems, other fire alarm systems, communication systems, various building automation systems, etc. The expansion is possible at any time and involves the purchase of additional licenses or GEMOS hardware components.

MSL-2M 4 Loop Module for POLON 4900

Price: 135,00 EUR
4 loops module (for POLON 4900(S) only)

ADC-4001M Conventional Line Interface

Price: 36,30 EUR
The ADC-4001M adapter works in detector lines/loops of the POLON 4000 control panels. It is designed to transfer information about the status of the detector line connected to the adapter, so called ‘side line’ (conventional), as well as about the status of the POLON-ALFA produced non-addressable double-status 30 or 40 model range detectors installed in thisline. The ADC-4001M unit also enables the following: creation of an intrinsically safe detector line by installing in an side line intrinsic detectors or call points behind an intrinsically safe barrier; connection of additional, atypical equipment (e.g. gas detectors, cable detectors), to the fire alarm system installation as well as creating hierarchical systems for small satellite panels. The ADC-4001M adapter is installed in the G-40 base. Operation voltage 16.5V -24V Max side line load current (at choice) 0.15mA or 0.3mA or 1mA or 2mA Max side line resistance max 2 x 25 Ohm Operating temperature from -25°C to 55°C Dimensions (without base) (mm) Ø 115 x 133 Weight 0.13kg

WZ-31 Remote Alarm Indicator

Price: 1,47 EUR
• additi onal opti cal alarm noti fi cati on • small dimensions • powered from the connected detector Max. current of remote alarm indicator 20µA Max. cross-section of connected wires 1.5 mm2 Colour milky Dimensions Ф 47x26 mm